VES-MATIC CUBE 80

Automatic instrument for the determination of the ESR directly on the hematocrit tube (95 samples/hour), using dedicated racks. The first result is performed after 26 minutes. Host query interface.
  • AUTOMATED

    Automated system for the direct determmination of ESR in blood/EDTA samples.

  • FLEXIBILITY, VERSATILITY AND HIGH PRODUCTIVITY

    Different models and brands of EDTA tubes can be processed simultaneously by the instrument, without restrictions suitable for laboratories receiving samples from different collection points greater sample stability: the test can be performed within up to 24 hours from blood collection. The complete disaggregation of erythrocytes first result obtained in 22 minutes only

  • NO BIOLOGICAL RISK

    ESR is determined in the same full cell count closed tube: No contact with blood; No blood is withdrawn; No liquid waste is produced.

Standard applicati

  • 98/79/EEC “directive relevant to the In Vitro Medical-Diagnostic Devices (IVD)”
  • - EN 61010-1 (CEI 66-5) “Safety requirements for electrical equipment for measurement,
  • control laboratory use – Part 1: General requirements”. The instrument is classified in Class I
  • - EN 61010-2-081 Safety requirements for electrical equipment for measurement, control and
  • laboratory use - Part 2-081: Particular requirements for automatic and semi-automatic
  • laboratory equipment for analysis and other purposes.
  • - EN 61010-2-101 “Safety requirements for electrical equipment for measurement, control and
  • laboratory use – Part 2-101: Particular requirementsfor In Vitro Diagnostic (IVD) medical
  • equipment”.
  • - EN 61326-1 “Electrical Equipment for Measurement, Control, and Laboratory Use –
  • Electromagnetic compatibility requirements-Part 1: General requirements”
  • - EN 61326-2-6 “Electrical Equipment for Measurement, Control, and Laboratory Use –
  • Electromagnetic compatibility requirements-Part 2-6: In Vitro Diagnostic (IVD) medical
  • equipment”
  • - 2014/35/EU “Low Voltage Directive”
  • - 2014/30/EU “Electromagnetic Compatibility Directive”
  • - 2011/65/EU “Restriction of Hazardous Substances in Electrical and Electronic Equipment
  • Directive – RoHS2”
  • - ICSH recommendations for modified and alternate methods measuring the erythrocyte
  • sedimentation rate. Int J Lab Hem. 2017;1–10. A. Kratz 1 et all.
  • - NCCLS H02-A5 Procedures for ESR; approved standard – fifth edition

Data sheet

SIZE
650 x 580 x 690 mm ( l x h x d )
WEIGHT
57,5 Kg
POWER SUPPLY
110/230 V ac
POWER CONSUMPTION
265 VA
BAR-CODE READER
AUTOMATIC INTERNAL
NOISE LEVEL
78 dBa
DISPLAY
TFT 800x 600 colour with Touch Screen
PRINTER
Alphanumeric with thermal paper 58 mm wide, 36 characters per line, speed 20 mm / sec.
INTERFACE
2 x RS232C, 2 USB Host, 1 USB Client, 1 Slot Compact Flash
PROTECTION CATEGORY
CLASS I

Accessori

10290
TEST DEVICE 10K
Dedicated tube with transponder RF. To be used only once to charge the VES-Matic Cube systems with the exact number of tests. (Not compatible with MINI-CUBE instrument).
10291
TEST DEVICE 5K
Dedicated tube with transponder RF. To be used only once to charge the VES-Matic Cube systems with the exact number of tests. (Not compatible with MINI-CUBE instrument).
10292
TEST DEVICE 1K
Dedicated tube with transponder RF. To be used only once to charge the VES-Matic Cube systems with the exact number of tests. (Not compatible with MINI-CUBE instrument).
10403
THERMAL PAPER VES
Paper rolls for thermal printer in Ves-Matic Cube and Ves-Matic Original instruments.

Video